{"product_id":"easytouch-difference-difference-weighing-e-g-the-growth-of-cell-cultures","title":"EasyTouch Difference – Difference weighing e.g. the growth of cell cultures","description":"\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eNote: Prerequisite for this set is the basic program SET-01 Base\u003c\/li\u003e\n\u003cli\u003eThe difference function supports monitoring and evaluation of growth or change processes, as could occur, for example, in biological test sequences with cell cultures (monitoring). In this function, any number of sample carriers, e.g. Petri dishes with culture media can be defined, named and the corresponding initial weight recorded. The samples to be monitored are added to these sample carriers and the initial weights are recorded. Using the Difference function, these sample carriers can be weighed again and again at regular intervals. The Difference function automatically calculates the weight difference, i.e. the difference compared with the initial weight (e.g. the growth or other biological, chemical changes). These differences are saved and evaluated. Statistical evaluation of any differences can be downloaded as graphics and as data\u003c\/li\u003e\n\u003cli\u003eGraphical step-by-step instructions: The illustrated guide takes the user safely through the workflow when using difference weighing\u003c\/li\u003e\n\u003cli\u003eRepeating weighing sequences: Sample carriers with cell cultures can be weighed as often as required and can therefore be monitored for as long as you want\u003c\/li\u003e\n\u003cli\u003eRecalling the relevant sample carrier can be carried out either automatically, in accordance with the defined sequence, or manually using the ID number of the sample carrier, which can be scanned using a barcode, for example. In this way, the risk of confusion and missed weighings is minimised\u003c\/li\u003e\n\u003cli\u003eCentral master data\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e: These weighing sequences can be stored in the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eof the system with the number of the containers (e.g. petri dishes), container IDs, ID number of the sequence, name of the sequence, batch name, etc.. In this way the data for this sequence does not have to be entered again for each repeated sequence, but can be easily recalled from the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e. The tare values for the petri dishes can also be stored in the master data\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e. These are then automatically deducted from each weighing result\u003c\/li\u003e\n\u003cli\u003eEfficient weighing and saving of individual results: Sample holders can be stored with an ID number which can be scanned as a barcode to identify the correct sample holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBasic and advanced modes: quick and easy to use in everyday working life\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasyTouch is used in many professional applications to support weighing processes. The user's focus is usually on another primary activity – the weighing process is simply an integrated sub-step. This is why it should be as simple, clear and designed for error-free use as possible\u003c\/li\u003e\n\u003cli\u003eThe so-called basic mode reduces the user interface to the essentials and ensures simple, user-friendly operation. Procedure in basic mode: In basic mode, the user simply selects the desired item, for example by scanning a barcode. The system then automatically performs the assigned function, such as weighing, piece counting,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"The lower and upper limiting values are programmed individually. Input is possible in gram, pieces or %. With tolerance checks such as dosing, portioning or sorting, the balance displays the value over or under the limits. (also see Weighing with tolerance ranges)\" aria-expanded=\"false\"\u003etolerance checks\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eor other specific processes. The data is then saved - that's it. This automated procedure minimises sources of error and significantly optimises the workflow\u003c\/li\u003e\n\u003cli\u003eAll functions are fully available in advanced mode. It is ideal for experienced users who regularly work with more complex requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptions\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe central data\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efunction Save Server (SET-10) for additional storage of all measurement data in a central, local server directory. By doing this the measurement data of all connected EasyTouch weighing systems as well as from all installed EasyTouch functions will be stored. A particular benefit of doing this for those users with several weighing systems is that all weighing data is consolidated in just one database and you can search for individual measurement data from several balances in just one table. The Save Server data\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.kern-sohn.com\/shop\/en\/products\/software\/kern-software\/tset-022-b\/#\" data-tippy-content=\"Balance contains memories, e.g. for item data, weighing data, tare weights etc.\u0026lt;br\u0026gt; ➔ PLU\" aria-expanded=\"false\"\u003ememory\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis also tamper-proof and cannot be changed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLicense information\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLicensing: One license can be operated on up to four terminal devices (PC, laptop, tablet) at the same time, working independently\u003c\/li\u003e\n\u003cli\u003eUser: You can store as many users as you need in one license\u003c\/li\u003e\n\u003cli\u003eBalances: You can store and operate as many balances as you need in one license\u003c\/li\u003e\n\u003cli\u003eCommunication between balance\/terminal device: The balance(s) can communicate with the PC, laptop or tablet by serial connection, USB, Bluetooth, Ethernet or WiFi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/SL_SET-22_en.pdf?v=1773738114\" target=\"_blank\" title=\"EasyTouch SET-22\" rel=\"noopener\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=f9QfZYmbT4k\u0026amp;embeds_referring_euri=https%3A%2F%2Fwww.kern-sohn.com%2F\" target=\"_blank\" rel=\"noopener\"\u003eVideo\u003c\/a\u003e\u003c\/h3\u003e","brand":"Kern","offers":[{"title":"Default Title","offer_id":59193348718926,"sku":"SET-22","price":242.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/SET-22.png?v=1773738221","url":"https:\/\/trisense.ee\/en\/products\/easytouch-difference-difference-weighing-e-g-the-growth-of-cell-cultures","provider":"Trisense","version":"1.0","type":"link"}