{"product_id":"msr145-data-logger-with-four-analogue-inputs-0-12-v-and-20-cm-cable","title":"MSR145 Data Logger with Four Analogue Inputs (0–12 V) and 20 cm Cable","description":"\u003ch3\u003e\u003cspan\u003eData logger for four analogue 0–12 V signals, with a 20 cm connection cable and a 230 mAh rechargeable battery. Select recording rates up to 50 Hz and analyse the stored measurements via USB.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe E6666\/020 connection equips this MSR145 with four analogue voltage inputs, each covering 0–12 V. Its 20 cm cable brings compatible external signal sources into a compact, battery-powered recording system. Select recording intervals from 50 readings per second to one reading every 12 hours and store more than two million measured values internally. External sensors or signal sources are required separately.\u003c\/p\u003e\n\u003cp\u003eThe B15 polycarbonate housing has an IP60 rating, meaning it is dust-tight but has no water-protection rating. The 230 mAh lithium-polymer battery is recharged through USB, which also transfers recorded data to a PC. Included MSR PC Software Pro provides setup and analysis. The four inputs are the selected 0–12 V configuration, rather than a user-switchable set of all the voltage and current options in the product family.\u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eFour separate analogue inputs covering 0–12 V\u003c\/li\u003e\n\u003cli\u003e20 cm cable for connection to compatible signal sources\u003c\/li\u003e\n\u003cli\u003eRecording rate up to 50 Hz\u003c\/li\u003e\n\u003cli\u003eMore than two million measured values in internal memory\u003c\/li\u003e\n\u003cli\u003eUSB charging and included configuration and analysis software\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buttons\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"copy-text\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/affiliate\/en\/msr145.php?ver=trisense\" title=\"MSR145 CONFIGURATOR\" rel=\"noopener\" target=\"_blank\"\u003eCONFIGURE YOUR OWN DEVICE \u0026gt;\u0026gt;\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMSR Electronics GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e145B15 \u0026amp; E6666\/020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate, not encapsulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e230 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions of data logger (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e27 × 16 × 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate data logger housing weight\u003c\/th\u003e\n\u003ctd\u003e20 g; connected sensor assemblies add weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature of data logger\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage conditions\u003c\/th\u003e\n\u003ctd\u003e+5 to +45 °C; 10–95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal memory\u003c\/th\u003e\n\u003ctd\u003eOver 2,000,000 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC requirement\u003c\/th\u003e\n\u003ctd\u003eWindows 10 or higher for current MSR PC Software Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue inputs\u003c\/th\u003e\n\u003ctd\u003e4 × 0–12.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue resolution\u003c\/th\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue interval\u003c\/th\u003e\n\u003ctd\u003e0.02 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component E6666\/020\u003c\/th\u003e\n\u003ctd\u003e1 × E6666\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity accuracy H3\/FH3\u003c\/th\u003e\n\u003ctd\u003e±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity sensor temperature limits\u003c\/th\u003e\n\u003ctd\u003eExternal: −40 to +125 °C; internal: −20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute air pressure range\u003c\/th\u003e\n\u003ctd\u003e10–2,000 mbar absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure accuracy\u003c\/th\u003e\n\u003ctd\u003e±2 mbar at 750–1,100 mbar absolute and +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight range\u003c\/th\u003e\n\u003ctd\u003e0–83,000 lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight sensitivity\u003c\/th\u003e\n\u003ctd\u003eMaximum at 550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIncluded configuration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMSR145 data logger in the specified housing with rechargeable battery\u003c\/li\u003e\n\u003cli\u003eSelected sensors and connections listed in this configuration\u003c\/li\u003e\n\u003cli\u003eMSR PC software (download)\u003c\/li\u003e\n\u003cli\u003eUSB connection cable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eRequirements and accessories\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 or higher with USB connection for current MSR PC Software Pro\u003c\/li\u003e\n\u003cli\u003eSuitable external signal sources; observe the configured input voltage range\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eDocuments and resources\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/product\/datalogger-temperature-humidity-pressure-acceleration-msr145\/\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer product page\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/Datalogger-MSR145-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eData sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/massblaetter\/MSR145B15-B16-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eDimensional drawing\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-logger-transport-monitoring\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 1\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-loggers-detect-moisture-damage\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 2\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/datalogger-food-process-engineering\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 3\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BFYs3JGYVAQ\" rel=\"noopener\" target=\"_blank\"\u003eMSR PC Software Pro tutorial\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/MSR145-V6-Brief-instructions-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eBrief instructions\u003c\/a\u003e\u003c\/div\u003e","brand":"MSR Electronics","offers":[{"title":"Default Title","offer_id":61764074307918,"sku":"145B15 \u0026 E6666\/020","price":455.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/93ac1c61e6-Datenlogger-MSR145-SmartCase.jpg?v=1795251595","url":"https:\/\/trisense.ee\/en\/products\/msr145-data-logger-with-four-analogue-inputs-0-12-v-and-20-cm-cable","provider":"Trisense","version":"1.0","type":"link"}