{"product_id":"msr145-data-logger-with-four-analogue-inputs-and-20-cm-cable","title":"MSR145 Data Logger with Four Analogue Inputs and 20 cm Cable","description":"\u003ch3\u003e\u003cspan\u003eCompact data logger with four analogue voltage inputs, each configured for 0–3 V, on a 20 cm cable. Records at up to 50 readings per second and stores more than two million measured values.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis MSR145 is configured to record four analogue voltage signals from 0 to 3 V through the E3333\/020 connection. The 20 cm cable connects the data logger to compatible external signal sources or sensors; those external sensors are not included. Recording intervals can be selected from 50 readings per second to one reading every 12 hours. More than two million measured values can be stored internally.\u003c\/p\u003e\n\u003cp\u003eThe B15 polycarbonate housing contains a 230 mAh rechargeable battery. IP60 means the housing is dust-tight, with no water-protection rating. USB provides charging and data transfer, and the included MSR PC Software Pro supports configuration and evaluation of the recorded signals. This configuration is supplied with four 0–3 V inputs; it does not include the other voltage or current ranges offered elsewhere in the MSR145 range.\u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eFour analogue channels configured for 0–3 V signals\u003c\/li\u003e\n\u003cli\u003e20 cm connection cable\u003c\/li\u003e\n\u003cli\u003eRecording rate up to 50 Hz\u003c\/li\u003e\n\u003cli\u003eCompact, battery-powered acquisition with USB recharge\u003c\/li\u003e\n\u003cli\u003eIncluded MSR PC Software Pro for setup and evaluation\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buttons\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"copy-text\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/affiliate\/en\/msr145.php?ver=trisense\" title=\"MSR145 CONFIGURATOR\" rel=\"noopener\" target=\"_blank\"\u003eCONFIGURE YOUR OWN DEVICE \u0026gt;\u0026gt;\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMSR Electronics GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e145B15 \u0026amp; E3333\/020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate, not encapsulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e230 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions of data logger (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e27 × 16 × 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate data logger housing weight\u003c\/th\u003e\n\u003ctd\u003e20 g; connected sensor assemblies add weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature of data logger\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage conditions\u003c\/th\u003e\n\u003ctd\u003e+5 to +45 °C; 10–95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal memory\u003c\/th\u003e\n\u003ctd\u003eOver 2,000,000 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC requirement\u003c\/th\u003e\n\u003ctd\u003eWindows 10 or higher for current MSR PC Software Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue inputs\u003c\/th\u003e\n\u003ctd\u003e4 × 0–3.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue resolution\u003c\/th\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue interval\u003c\/th\u003e\n\u003ctd\u003e0.02 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component E3333\/020\u003c\/th\u003e\n\u003ctd\u003e1 × E3333\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity accuracy H3\/FH3\u003c\/th\u003e\n\u003ctd\u003e±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity sensor temperature limits\u003c\/th\u003e\n\u003ctd\u003eExternal: −40 to +125 °C; internal: −20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute air pressure range\u003c\/th\u003e\n\u003ctd\u003e10–2,000 mbar absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure accuracy\u003c\/th\u003e\n\u003ctd\u003e±2 mbar at 750–1,100 mbar absolute and +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight range\u003c\/th\u003e\n\u003ctd\u003e0–83,000 lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight sensitivity\u003c\/th\u003e\n\u003ctd\u003eMaximum at 550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIncluded configuration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMSR145 data logger in the specified housing with rechargeable battery\u003c\/li\u003e\n\u003cli\u003eSelected sensors and connections listed in this configuration\u003c\/li\u003e\n\u003cli\u003eMSR PC software (download)\u003c\/li\u003e\n\u003cli\u003eUSB connection cable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eRequirements and accessories\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 or higher with USB connection for current MSR PC Software Pro\u003c\/li\u003e\n\u003cli\u003eSuitable external signal sources; observe the configured input voltage range\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eDocuments and resources\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/product\/datalogger-temperature-humidity-pressure-acceleration-msr145\/\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer product page\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/Datalogger-MSR145-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eData sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/massblaetter\/MSR145B15-B16-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eDimensional drawing\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-logger-transport-monitoring\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 1\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-loggers-detect-moisture-damage\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 2\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/datalogger-food-process-engineering\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 3\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BFYs3JGYVAQ\" rel=\"noopener\" target=\"_blank\"\u003eMSR PC Software Pro tutorial\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/MSR145-V6-Brief-instructions-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eBrief instructions\u003c\/a\u003e\u003c\/div\u003e","brand":"MSR Electronics","offers":[{"title":"Default Title","offer_id":61764038656334,"sku":"145B15 \u0026 E3333\/020","price":455.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/93ac1c61e6-Datenlogger-MSR145-SmartCase.jpg?v=1795251595","url":"https:\/\/trisense.ee\/en\/products\/msr145-data-logger-with-four-analogue-inputs-and-20-cm-cable","provider":"Trisense","version":"1.0","type":"link"}