{"product_id":"msr145-type-k-thermocouple-data-logger-with-one-20-cm-connection","title":"MSR145 Type-K Thermocouple Data Logger with One 20 cm Connection","description":"\u003ch3\u003e\u003cspan\u003eData logger with one Type-K thermocouple connection on a 20 cm cable, supporting −200 to +1350 °C and up to four readings per second. A suitable thermocouple must be supplied separately.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis MSR145 configuration contains one FT3\/020 Type-K thermocouple connection on a 20 cm cable. It supports measurements from −200 to +1350 °C at up to four readings per second, with longer recording intervals available up to 12 hours. The usable temperature range also depends on the selected thermocouple, which is not included. The data logger must remain within its own −20 to +65 °C operating range.\u003c\/p\u003e\n\u003cp\u003eThe compact B15 polycarbonate housing contains a 230 mAh rechargeable battery and memory for more than two million measured values. IP60 means the housing is dust-tight, with no water-protection rating. USB is used for battery charging and data transfer. Included MSR PC Software Pro supports configuration and analysis of the temperature recordings.\u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eOne Type-K connection on a 20 cm cable\u003c\/li\u003e\n\u003cli\u003eSupports a wide −200 to +1350 °C measurement range with a suitable thermocouple\u003c\/li\u003e\n\u003cli\u003eRecording rate up to four readings per second\u003c\/li\u003e\n\u003cli\u003eMore than two million measured values stored internally\u003c\/li\u003e\n\u003cli\u003e230 mAh rechargeable battery and USB analysis\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buttons\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"copy-text\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/affiliate\/en\/msr145.php?ver=trisense\" title=\"MSR145 CONFIGURATOR\" rel=\"noopener\" target=\"_blank\"\u003eCONFIGURE YOUR OWN DEVICE \u0026gt;\u0026gt;\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMSR Electronics GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e145B15 \u0026amp; FT3\/020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate, not encapsulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e230 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions of data logger (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e27 × 16 × 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate data logger housing weight\u003c\/th\u003e\n\u003ctd\u003e20 g; connected sensor assemblies add weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature of data logger\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage conditions\u003c\/th\u003e\n\u003ctd\u003e+5 to +45 °C; 10–95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal memory\u003c\/th\u003e\n\u003ctd\u003eOver 2,000,000 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC requirement\u003c\/th\u003e\n\u003ctd\u003eWindows 10 or higher for current MSR PC Software Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType K measurement range\u003c\/th\u003e\n\u003ctd\u003e−200 to +1,350 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType K recording interval\u003c\/th\u003e\n\u003ctd\u003e0.25 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType K connection\u003c\/th\u003e\n\u003ctd\u003eOne FT3\/020 connection, 20 cm cable; thermocouple sensor not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component FT3\/020\u003c\/th\u003e\n\u003ctd\u003e1 × FT3\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWetted materials\u003c\/th\u003e\n\u003ctd\u003eStainless steel AISI 316L and Viton 70 Shore O-rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component FP4\/020\u003c\/th\u003e\n\u003ctd\u003e1 × FP4\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute air pressure range\u003c\/th\u003e\n\u003ctd\u003e10–2,000 mbar absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure accuracy\u003c\/th\u003e\n\u003ctd\u003e±2 mbar at 750–1,100 mbar absolute and +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight range\u003c\/th\u003e\n\u003ctd\u003e0–83,000 lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight sensitivity\u003c\/th\u003e\n\u003ctd\u003eMaximum at 550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIncluded configuration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMSR145 data logger in the specified housing with rechargeable battery\u003c\/li\u003e\n\u003cli\u003eSelected sensors and connections listed in this configuration\u003c\/li\u003e\n\u003cli\u003eMSR PC software (download)\u003c\/li\u003e\n\u003cli\u003eUSB connection cable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eRequirements and accessories\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 or higher with USB connection for current MSR PC Software Pro\u003c\/li\u003e\n\u003cli\u003eSuitable Type K thermocouple sensor, supplied separately\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eDocuments and resources\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/product\/datalogger-temperature-humidity-pressure-acceleration-msr145\/\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer product page\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/Datalogger-MSR145-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eData sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/massblaetter\/MSR145B15-B16-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eDimensional drawing\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-logger-transport-monitoring\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 1\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-loggers-detect-moisture-damage\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 2\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/datalogger-food-process-engineering\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 3\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BFYs3JGYVAQ\" rel=\"noopener\" target=\"_blank\"\u003eMSR PC Software Pro tutorial\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/MSR145-V6-Brief-instructions-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eBrief instructions\u003c\/a\u003e\u003c\/div\u003e","brand":"MSR Electronics","offers":[{"title":"Default Title","offer_id":61764120871246,"sku":"145B15 \u0026 FT3\/020","price":365.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/93ac1c61e6-Datenlogger-MSR145-SmartCase.jpg?v=1795251595","url":"https:\/\/trisense.ee\/en\/products\/msr145-type-k-thermocouple-data-logger-with-one-20-cm-connection","provider":"Trisense","version":"1.0","type":"link"}