{"product_id":"msr160-data-logger-with-four-analogue-inputs-1000-hz-per-channel","title":"MSR160 Data Logger with Four Analogue Inputs, 1000 Hz per Channel","description":"\u003ch3\u003e\u003cspan\u003eRecord four analogue 0–3 V signals at up to 1,000 readings per second per channel. This rechargeable data logger includes alarm and recording-control connections, more than two million values of internal storage and USB analysis software.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe MSR160 with E3333 is configured for four analogue voltage inputs, each covering 0–3 V. Sampling reaches 1,000 readings per second per channel, with slower intervals available up to 12 hours. It connects compatible external signal sources or sensors to a compact recording system; external sensors are not included. An alarm output and an input for starting and stopping recording support integration with the measurement setup.\u003c\/p\u003e\n\u003cp\u003eMore than two million measured values can be stored internally. This configuration uses internal memory and does not include the N10006 microSD expansion. The B7 housing is rated IP60: dust-tight, with no water-protection rating. The rechargeable battery is charged via USB, which also transfers data to a PC. Included MSR Setup, Reader, Viewer and Online software support configuration, readout and evaluation.\u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eFour analogue voltage channels configured for 0–3 V\u003c\/li\u003e\n\u003cli\u003eUp to 1,000 readings per second on each channel\u003c\/li\u003e\n\u003cli\u003eAlarm output and external recording start\/stop input\u003c\/li\u003e\n\u003cli\u003eMore than two million measured values in internal memory\u003c\/li\u003e\n\u003cli\u003eRechargeable operation, USB transfer and included MSR PC software\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial signal recording\u003c\/li\u003e\n\u003cli\u003eSensor evaluation\u003c\/li\u003e\n\u003cli\u003eMachine and process monitoring\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buttons\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"copy-text\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/affiliate\/en\/msr160.php?ver=trisense\" target=\"_blank\" title=\"MSR160 CONFIGURATOR\" rel=\"noopener\"\u003eCONFIGURE YOUR OWN DEVICE \u0026gt;\u0026gt;\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMSR Electronics GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel family\u003c\/th\u003e\n\u003ctd\u003eMSR160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e160B7 \u0026amp; E3333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory\u003c\/th\u003e\n\u003ctd\u003eMore than 2,000,000 measured values internally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue inputs\u003c\/th\u003e\n\u003ctd\u003e4 × 0–3 V (E3333); 12-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue sampling\u003c\/th\u003e\n\u003ctd\u003e1,000\/s per channel to every 12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl I\/O\u003c\/th\u003e\n\u003ctd\u003eAlarm output; recording start\/stop input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e39 × 23 × 72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate weight\u003c\/th\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e900 mAh rechargeable LiPo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\/protection\u003c\/th\u003e\n\u003ctd\u003eB7, non-encapsulated; IP60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e35 × 17 × 57 mm, data logger only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData Logger weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 36 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData Logger operating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity accuracy FH3.3\u003c\/th\u003e\n\u003ctd\u003e±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIncluded configuration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e1 × MSR160 data logger configured as 160B7 \u0026amp; E3333\u003c\/li\u003e\n\u003cli\u003eSpecified battery supply\u003c\/li\u003e\n\u003cli\u003eMSR PC software available for download\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eScrew set\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eRequirements and accessories\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWindows PC with USB port for configuration and data evaluation; verify current supported OS release\u003c\/li\u003e\n\u003cli\u003eCompatible external sensors or sources with 0–3 V outputs; these third-party sensors are not specified in this offer\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eDocuments and resources\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/product\/datalogger-analogue-inputs-msr160\/\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer product page\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/Data_logger_MSR160_Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eData sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/msr-data-loggers-product-optimisation-data-analysis\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 1\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/portfolio\/data-loggers-determine-load-values-in-filling-plants\/\" rel=\"noopener\" target=\"_blank\"\u003eApplication example 2\u003c\/a\u003e\u003c\/div\u003e","brand":"MSR Electronics","offers":[{"title":"Default Title","offer_id":61767062946126,"sku":"160B7 \u0026 E3333","price":1047.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/datalogger-analogue-inputs-msr160-1.jpg?v=1795269043","url":"https:\/\/trisense.ee\/en\/products\/msr160-data-logger-with-four-analogue-inputs-1000-hz-per-channel","provider":"Trisense","version":"1.0","type":"link"}