{"product_id":"msr145w2d-wi-fi-data-logger-with-four-analogue-inputs-control-terminal-and-flexconnector","title":"MSR145W2D Wi-Fi Data Logger with Four Analogue Inputs, Control Terminal and FlexConnector","description":"\u003ch3\u003e\u003cspan\u003eWi-Fi data logger combining four 0–3 V analogue inputs, a recording\/alarm control terminal and a FlexConnector for an optional sensor. Includes 20 cm connection cables, a colour OLED display and a 900 mAh rechargeable battery.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis MSR145W2D records four analogue 0–3 V signals through E3333\/020. The FY\/020 control terminal provides an alarm output, an external recording start\/stop input and a 3 V output. FX\/020 supplies a FlexConnector for a compatible interchangeable MSR FlexSensor, which must be chosen separately. Each of the three assemblies has a 20 cm cable. Recording intervals range from one second to 12 hours, with storage for more than one million measured values.\u003c\/p\u003e\n\u003cp\u003eA colour OLED display provides local checks, and Wi-Fi supports continuous or scheduled data transfer. Recorded values remain available locally if the network is interrupted; USB offers readout and charging. MSR LocalCloud or SmartCloud can be used with the necessary setup and service arrangements. The B23 housing contains a 900 mAh rechargeable battery. Its IP60 rating means the polycarbonate enclosure is dust-tight but has no water-protection rating.\u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eFour analogue inputs configured for 0–3 V\u003c\/li\u003e\n\u003cli\u003eAlarm output and external recording control through FY\/020\u003c\/li\u003e\n\u003cli\u003eFlexConnector for a separately selected FlexSensor\u003c\/li\u003e\n\u003cli\u003eWi-Fi transfer plus local memory and USB readout\u003c\/li\u003e\n\u003cli\u003eOLED display and larger 900 mAh rechargeable battery\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"buttons\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"copy-text\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/affiliate\/en\/msr145w2d.php?ver=trisense\" title=\"MSR145WD2D CONFIGURATOR\" rel=\"noopener\" target=\"_blank\"\u003eCONFIGURE YOUR OWN DEVICE \u0026gt;\u0026gt;\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMSR Electronics GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e145W2DB23 \u0026amp; E3333\/020 \u0026amp; FY\/020 \u0026amp; FX\/020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate, not encapsulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e900 mAh rechargeable lithium-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharging\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions of data logger (W × H × L)\u003c\/th\u003e\n\u003ctd\u003e35 × 25 × 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate data logger housing weight\u003c\/th\u003e\n\u003ctd\u003e43 g; connected sensor assemblies add weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature of data logger\u003c\/th\u003e\n\u003ctd\u003e−20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage conditions\u003c\/th\u003e\n\u003ctd\u003e+5 to +45 °C; 10–95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eUSB, WiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal memory\u003c\/th\u003e\n\u003ctd\u003eOver 1,000,000 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOLED display\u003c\/th\u003e\n\u003ctd\u003e96 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLogging interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePC requirement\u003c\/th\u003e\n\u003ctd\u003eWindows 10 or higher for current MSR PC Software Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue inputs\u003c\/th\u003e\n\u003ctd\u003e4 × 0–3.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue resolution\u003c\/th\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl terminal\u003c\/th\u003e\n\u003ctd\u003eAlarm output, start\/stop input and 3 V voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlexConnector\u003c\/th\u003e\n\u003ctd\u003eConnection for interchangeable MSR FlexSensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component E3333\/020\u003c\/th\u003e\n\u003ctd\u003e1 × E3333\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component FY\/020\u003c\/th\u003e\n\u003ctd\u003e1 × FY\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component FX\/020\u003c\/th\u003e\n\u003ctd\u003e1 × FX\/020; cable 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal component FH3\/100\u003c\/th\u003e\n\u003ctd\u003e2 × FH3\/100; cable 100 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure accuracy\u003c\/th\u003e\n\u003ctd\u003e±2 mbar at 750–1,100 mbar absolute and +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure sensor additional channel\u003c\/th\u003e\n\u003ctd\u003eIntegrated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir pressure interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAcceleration\u003c\/th\u003e\n\u003ctd\u003e3 axes; ±15 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAcceleration accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAcceleration recording interval\u003c\/th\u003e\n\u003ctd\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIncluded configuration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMSR145W2D data logger in the specified housing with rechargeable battery\u003c\/li\u003e\n\u003cli\u003eSelected sensors and connections listed in this configuration\u003c\/li\u003e\n\u003cli\u003eMSR PC software (download)\u003c\/li\u003e\n\u003cli\u003eUSB connection cable\u003c\/li\u003e\n\u003cli\u003eActivation key for free access to MSR SmartCloud\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eRequirements and accessories\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 or higher with USB connection for current MSR PC Software Pro\u003c\/li\u003e\n\u003cli\u003eCompatible WiFi network or access point for wireless transfer\u003c\/li\u003e\n\u003cli\u003eMSR SmartCloud account and activation are required if cloud transfer is used\u003c\/li\u003e\n\u003cli\u003eSuitable external signal sources; observe the configured input voltage range\u003c\/li\u003e\n\u003cli\u003eCompatible FlexSensor for use of the FlexConnector; no FlexSensor is included in this product code\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"section-head\"\u003e\n\u003ch3\u003eDocuments and resources\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/en\/product\/wifi-data-logger-msr145w2d\/\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer product page\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/Data-Logger-WiFi-MSR145W2D-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eData sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BFYs3JGYVAQ\" rel=\"noopener\" target=\"_blank\"\u003eMSR PC Software Pro tutorial\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"links\"\u003e\u003ca href=\"https:\/\/www.msr.ch\/media\/pdf\/MSR145W2D-Brief-instructions-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eBrief instructions\u003c\/a\u003e\u003c\/div\u003e","brand":"MSR Electronics","offers":[{"title":"Default Title","offer_id":61765322146126,"sku":"145W2DB23 \u0026 E3333\/020 \u0026 FY\/020 \u0026 FX\/020","price":702.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0883\/3528\/6606\/files\/109f6b99da-WiFi-datalogger-temperature-humidity-MSR145W2D.jpg?v=1795260251","url":"https:\/\/trisense.ee\/fi\/products\/msr145w2d-wi-fi-data-logger-with-four-analogue-inputs-control-terminal-and-flexconnector","provider":"Trisense","version":"1.0","type":"link"}