Description
- External sensor for difficult-to-access measuring points
- LCD display, backlit, display of all information at a glance
- Offset-Accur: This function allows you to adjust the instrument precisely on the locally measured range by a two-point calibration. This results in a superior accuracy of 1 % (or less) of the measured value
- Two different measuring modes: single measurement and scan mode for continuous measurement
- Mini Statistics Kit: displays the measured result, the average value and the max and the min value
- Internal memory for up to 99 measurement values
- Selectable measuring units: µm inch (mil)
- Base plate and calibration foils included
- Data interface RS-232 as standard
- Delivered in a robust carrying case
Technical Data
| Measuring range coating thickness [d] (µm) | 100 µm; 1250 µm |
| Readability coating thickness [d] (µm) | 0,1 µm; 1 µm |
| Tolerance (% of [Max]) | 3% |
| Units | µm, inch (mil) |
| Coating thickness gauge sensor type | FE, NFE |
| Test object thickness coating | Non-magnetic coatings on iron, steel, Type F, Coatings on non-magnetic metals, type N |
| Battery | 2×1.5 V AAA |
| Memory function | |
| Statistic function | |
| Increase in measurement accuracy possible | |
| Continuous capture possible | |
| Material housing | plastic |
| Dimensions completely mounted (W×D×H) | 130×64×32 mm |
| Cable length | 1 m |
| Sensor placement position | external |