MSR145 IP67 Temperature, Humidity, Pressure and Acceleration Data Logger
Four measured quantities in a slim silicone-tube data logger: temperature, relative humidity, absolute air pressure and three-axis acceleration. Combines a 230 mAh rechargeable battery with memory for more than two million measured values.
The 145B4T9H3P5A brings together internal temperature, humidity, absolute air-pressure and three-axis acceleration sensors. It records −20 to +65 °C, 0–100% RH, 10–2,000 mbar absolute and ±15 g, allowing changes in environmental conditions to be compared with movement and orientation. Acceleration can be recorded up to 50 times per second; the environmental channels support up to one reading per second, with longer intervals selectable up to 12 hours.
The slim silicone-tube housing is encapsulated and rated IP67: dust-tight and protected against temporary immersion under specified test conditions. The 230 mAh battery recharges via USB, and more than two million measured values can be retained in internal memory. The button and status LEDs support operation on the device. Included MSR PC Software Pro handles configuration and analysis after USB data transfer.
Benefits
- Temperature, humidity, absolute air pressure and three-axis acceleration in one device
- Compare environmental changes with movement and orientation
- Acceleration recording up to 50 Hz
- Slim silicone-tube housing and USB-rechargeable battery
- Internal memory for more than two million measured values
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Product code | 145B4T9H3P5A |
| Housing | Silicone tube, encapsulated |
| Protection rating | IP67 |
| Battery | 230 mAh rechargeable lithium-polymer |
| Charging | USB |
| Dimensions of data logger (W × H × L) | 20 × 14 × 62 mm |
| Approximate data logger housing weight | 18 g; connected sensor assemblies add weight |
| Operating temperature of data logger | −20 to +65 °C |
| Storage conditions | +5 to +45 °C; 10–95 % RH, non-condensing |
| Interfaces | USB |
| Internal memory | Over 2,000,000 measured values |
| PC requirement | Windows 10 or higher for current MSR PC Software Pro |
| Internal temperature range | −20 to +65 °C |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Temperature interval | 1 second to 12 hours |
| Relative humidity range | 0–100 % RH |
| Humidity accuracy H3/FH3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Humidity sensor temperature limits | External: −40 to +125 °C; internal: −20 to +65 °C |
| Humidity interval | 1 second to 12 hours |
| Humidity sensor additional channel | Integrated temperature |
| Absolute air pressure range | 10–2,000 mbar absolute |
| Air pressure accuracy | ±2 mbar at 750–1,100 mbar absolute and +25 °C |
| Pressure sensor additional channel | Integrated temperature |
| Air pressure interval | 1 second to 12 hours |
| Acceleration | 3 axes; ±15 g |
| Acceleration accuracy | ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C |
| Acceleration recording interval | 0.02 second to 12 hours |
Included configuration
- MSR145 data logger in the specified housing with rechargeable battery
- Selected sensors and connections listed in this configuration
- MSR PC software (download)
- USB connection cable
Requirements and accessories
- Windows 10 or higher with USB connection for current MSR PC Software Pro