MSR145W2D Wi-Fi Strain-Gauge Data Logger with OLED Display

SKU: 145W2DB25 & FD/020
Regular price 427.00 € (ex VAT)

Wi-Fi data logger with one 20 cm connection for a compatible full-bridge strain gauge and a 3 V bridge supply. Offers OLED readout, local memory and scheduled wireless transfer; the strain gauge is not included.

 

This MSR145W2D connects to one compatible full-bridge strain gauge through FD/020, a 20 cm cable assembly with a 3 V bridge supply. Recording intervals range from one second to 12 hours, and more than one million measured values can be stored. The strain gauge is required separately; check its compatibility against the confirmed FD specification.

The OLED display provides local readings, while Wi-Fi allows scheduled transfer or continuous observation through the supported MSR software. Local memory preserves recorded data during a Wi-Fi interruption, with USB available for readout. Data can be managed through MSR LocalCloud or SmartCloud after the necessary setup and service arrangements.

A 230 mAh rechargeable battery powers the B25 device and charges via USB. Its polycarbonate housing is rated IP60, meaning it is dust-tight but has no water-protection rating. MSR PC and WLAN software support setup and analysis.

Benefits

  • One full-bridge connection with a 20 cm cable and 3 V supply
  • OLED readings and Wi-Fi access
  • Scheduled transfer can reduce wireless power consumption
  • Local memory and USB readout when Wi-Fi is unavailable
  • Support for MSR LocalCloud and SmartCloud

 



CONFIGURE YOUR OWN DEVICE >>

 

 

Technical specifications

Manufacturer MSR Electronics GmbH
Product code 145W2DB25 & FD/020
Housing Polycarbonate, not encapsulated
Protection rating IP60
Battery 230 mAh rechargeable lithium-polymer
Charging USB
Dimensions of data logger (W × H × L) 35 × 17 × 57 mm
Approximate data logger housing weight 27 g; connected sensor assemblies add weight
Operating temperature of data logger −20 to +65 °C
Storage conditions +5 to +45 °C; 10–95 % RH, non-condensing
Interfaces USB, WiFi
Internal memory Over 1,000,000 measured values
OLED display 96 × 64 pixels
Logging interval 1 second to 12 hours
PC requirement Windows 10 or higher for current MSR PC Software Pro
Strain gauge connection Full bridge; rated output 1–4 mV/V; bridge voltage 3 V
Strain gauge interval 1 second to 12 hours
External component FD/020 1 × FD/020; cable 20 cm
Relative humidity range 0–100 % RH
Humidity accuracy H3/FH3 ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C)
Humidity sensor temperature limits External: −40 to +125 °C; internal: −20 to +65 °C
Humidity interval 1 second to 12 hours
Humidity sensor additional channel Integrated temperature
Absolute air pressure range 10–2,000 mbar absolute
Air pressure accuracy ±2 mbar at 750–1,100 mbar absolute and +25 °C
Pressure sensor additional channel Integrated temperature
Air pressure interval 1 second to 12 hours
Acceleration 3 axes; ±15 g
Acceleration accuracy ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C
Acceleration recording interval 1 second to 12 hours


 

Included configuration

  • MSR145W2D data logger in the specified housing with rechargeable battery
  • Selected sensors and connections listed in this configuration
  • MSR PC software (download)
  • USB connection cable
  • Activation key for free access to MSR SmartCloud

Requirements and accessories

  • Windows 10 or higher with USB connection for current MSR PC Software Pro
  • Compatible WiFi network or access point for wireless transfer
  • MSR SmartCloud account and activation are required if cloud transfer is used
  • Compatible full-bridge strain gauge; the product code specifies the connection, not a strain gauge sensor