MSR145WD Bluetooth Strain-Gauge Data Logger with OLED Display
Monitor a compatible full-bridge strain gauge through one 20 cm connection, with readings on the OLED display or via Bluetooth. Includes a 3 V bridge supply and a 230 mAh rechargeable battery; the strain gauge is supplied separately.
The MSR145WD in this configuration has one FD/020 connection for a full-bridge strain gauge, on a 20 cm cable with a 3 V bridge supply. It records at intervals from one second to 12 hours and stores more than one million measured values. The strain gauge is not included; its compatibility must be checked against the confirmed FD specification.
The colour OLED display shows measurements and graphs locally, while Bluetooth Low Energy and the MSR DataLogger app provide wireless access. USB allows PC readout and recharges the 230 mAh battery. The B25 polycarbonate housing is rated IP60: dust-tight, with no water-protection rating. MSR PC software is included for setup and evaluation. SmartCloud use requires the appropriate app or optional gateway route and service arrangements; a BLE/LAN gateway is not part of this configuration.
Benefits
- One full-bridge strain-gauge connection with 20 cm cable
- 3 V bridge supply
- OLED display and Bluetooth access to measurements
- More than one million measured values stored internally
- USB-rechargeable battery and included MSR PC software
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Product code | 145WDB25 & FD/020 |
| Housing | Polycarbonate, not encapsulated |
| Protection rating | IP60 |
| Battery | 230 mAh rechargeable lithium-polymer |
| Charging | USB |
| Dimensions of data logger (W × H × L) | 35 × 17 × 57 mm |
| Approximate data logger housing weight | 27 g; connected sensor assemblies add weight |
| Operating temperature of data logger | −20 to +65 °C |
| Storage conditions | +5 to +45 °C; 10–95 % RH, non-condensing |
| Interfaces | USB, Bluetooth Low Energy |
| Internal memory | Over 1,000,000 measured values |
| OLED display | 96 × 64 pixels |
| Logging interval | 1 second to 12 hours |
| PC requirement | Windows 10 or higher for current MSR PC Software Pro |
| Strain gauge connection | Full bridge; rated output 1–4 mV/V; bridge voltage 3 V |
| Strain gauge interval | 1 second to 12 hours |
| External component FD/020 | 1 × FD/020; cable 20 cm |
| Relative humidity range | 0–100 % RH |
| Humidity accuracy H3/FH3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Humidity sensor temperature limits | External: −40 to +125 °C; internal: −20 to +65 °C |
| Humidity interval | 1 second to 12 hours |
| Humidity sensor additional channel | Integrated temperature |
| Absolute air pressure range | 10–2,000 mbar absolute |
| Air pressure accuracy | ±2 mbar at 750–1,100 mbar absolute and +25 °C |
| Pressure sensor additional channel | Integrated temperature |
| Air pressure interval | 1 second to 12 hours |
| Acceleration | 3 axes; ±15 g |
| Acceleration accuracy | ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C |
| Acceleration recording interval | 1 second to 12 hours |
Included configuration
- MSR145WD data logger in the specified housing with rechargeable battery
- Selected sensors and connections listed in this configuration
- MSR PC software (download)
- USB connection cable
- Activation key for free access to MSR SmartCloud
Requirements and accessories
- Windows 10 or higher with USB connection for current MSR PC Software Pro
- Compatible mobile device and MSR DataLogger app for Bluetooth access
- MSR SmartCloud account and activation are required if cloud transfer is used; a BLE gateway is optional
- Compatible full-bridge strain gauge; the product code specifies the connection, not a strain gauge sensor