MSR165 ±15 g Shock and Climate Data Logger with microSD and Extended Battery Supply
Long-duration shock and vibration configuration with two replaceable 5,800 mAh batteries and microSD storage beyond one billion measured values. Records ±15 g acceleration, temperature, humidity and absolute air pressure.
This MSR165 pairs a three-axis ±15 g acceleration sensor with temperature, humidity and absolute air-pressure measurement. Acceleration records at up to 1,600 readings per second, with 32 values retained before a shock trigger. The environmental channels cover −20 to +65 °C, 0–100% RH and 10–2,000 mbar absolute, at intervals from one second to 12 hours.
The B52 power option uses two replaceable 5,800 mAh Li-SOCl₂ batteries in a splashproof cast-aluminium case. MSR quotes shock-monitoring periods of up to five years with this power option, depending on the measurement rate and setup; this is not a guarantee of uninterrupted full-rate recording. N10006 adds a formatted microSD card of at least 4 GB and expands storage beyond one billion measured values. The card can be replaced during operation.
The microSD slot with card is rated IP60: dust-tight, with no water-protection rating. Use USB or the card to transfer recordings, then analyse shock-mode data with the included MSR PC software and ShockViewer.
Benefits
- Two replaceable 5,800 mAh batteries for extended monitoring
- ±15 g shock data with temperature, humidity and air pressure
- Up to 1,600 Hz acceleration and 32 pre-trigger values
- Included microSD expansion with over one billion values of storage
- Splashproof battery case and included analysis software
Applications
- Transport monitoring
- Machine fault diagnosis
- Load and vibration investigations
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Model family | MSR165 |
| Product code | 165B52T9H3P5A & N10006 |
| Memory | More than 2,000,000 measured values internally; more than 1 billion with included microSD expansion |
| Memory extension | N10006; ≥4 GB formatted microSD card; exposed slot rated IP60 |
| Acceleration range | ±15 g, three axes |
| Acceleration resolution | 13 bit |
| Acceleration measurement/storage rate | Up to 1,600/s (±15%) to every 12 h |
| Acceleration accuracy at +25 °C | ±0.15 g (0–5 g); ±0.3 g (5–15 g) |
| Pre-trigger recording | 32 values before the shock event |
| Temperature range | −20 to +65 °C |
| Humidity range | 0–100 % RH |
| Pressure range | 10–2,000 mbar absolute |
| Environmental sensor recording interval | 1 second to 12 hours |
| Operating temperature | −20 to +65 °C |
| Interface | USB |
| Dimensions (W × H × L) | 122 × 92 × 70 mm |
| Approximate weight | 530 g |
| Battery | 2 × 5,800 mAh replaceable Li-SOCl₂, 3.6 V |
| Housing/protection | Splashproof cast aluminium battery housing; microSD slot IP60 |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Humidity accuracy H3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Air pressure accuracy P5 | ±2 mbar (750–1,100 mbar absolute, +25 °C) |
| Air pressure accuracy P5 | ±2 mbar (750–1,100 mbar absolute, +25 °C) |
Included configuration
- 1 × MSR165 data logger configured as 165B52T9H3P5A & N10006
- Specified battery supply
- MSR PC software available for download
- N10006 expansion and one formatted microSD card, at least 4 GB
- USB cable
- Screw set
- Transport case
- Quick start guide
Requirements and accessories
- Windows PC with USB port for configuration and data evaluation; verify current supported OS release
- Observe IP60 (dust-tight, with no water protection rating) limitation at the microSD slot