Overview
- differential pressure 0...60 mbar up to 0...20 bar
- accuracy: 0,1%
- static over pressure 400 bar
- two chamber aluminium die cast case
- HART communication
- output signal: linear or square root extraction
- explosion protection, intrinsic safety Exia
- flameproof enclosure Ex d
- optional SIL 2 version according to IEC 61508
- with integrated display and operating module
- areas of application: mechanical and plant engineering, chemical industry, energy industry, HVAC, food and beverage
Description
The differential pressure transmitter XMD has been especially designed for the process industry and can be used for level measurement of closed, pressurized tanks, pump or filter controlling, etc.
Another attribute is the possibility to switch the output signal from linear to square root extraction by what the flow rate of the medium can be issued.
Specification
Measurement range |
0...60 mbar up to 0...20 bar
|
Output type |
4...20 mA, 2-wire
HART
|
Process connection |
1/4 NPT
|
Electrical connection |
terminal clamp
|
Diaphragm |
stainless steel 316L
Hastelloy C 276
|
Power supply |
12...28V DC
13…28V DC
|
Display |
LCD, 5 x 8 mm
LCD, 8 x 5 mm
52-points bargraph
|
Accuracy |
±0,1%
|
Operating temperature |
-20…+65°C
-40...+85°C
-40...+100°C
|
Medium temperature |
-40...+85°C
|
Protection class |
IP 67
|
Case material |
stainless steel
|
Files
Data sheet | |
Manual IS version | |
Declaration of conformity |