MSR145 Humidity Data Logger with Temperature Measurement

Tuotenumero: 145B15H3
Normaali hinta 285.00 € (ex VAT)

Compact data logger with an internal relative-humidity sensor covering 0–100% RH and integrated temperature measurement. Features a 230 mAh rechargeable battery, USB transfer and memory for more than two million measured values.

 

The 145B15H3 records relative humidity from 0 to 100% RH. Temperature measurement is integrated into the H3 humidity sensor, with an internal operating range of −20 to +65 °C; a separate T9 temperature sensor is not fitted. Select a recording interval from one second to 12 hours for humidity monitoring.

The small B15 polycarbonate housing contains a 230 mAh lithium-polymer battery rechargeable through USB. Its IP60 rating means the housing is dust-tight but has no water-protection rating. Internal memory holds more than two million measured values. Transfer recorded values through USB and use the included MSR PC Software Pro for setup and analysis.

Benefits

  • Relative-humidity measurement from 0 to 100% RH
  • Temperature measurement integrated into the humidity sensor
  • Compact housing with a 230 mAh rechargeable battery
  • Selectable intervals from one second to 12 hours
  • USB transfer and included MSR PC Software Pro



CONFIGURE YOUR OWN DEVICE >>

 

 

Technical specifications

Manufacturer MSR Electronics GmbH
Product code 145B15H3
Housing Polycarbonate, not encapsulated
Protection rating IP60
Battery 230 mAh rechargeable lithium-polymer
Charging USB
Dimensions of data logger (W × H × L) 27 × 16 × 53 mm
Approximate data logger housing weight 20 g; connected sensor assemblies add weight
Operating temperature of data logger −20 to +65 °C
Storage conditions +5 to +45 °C; 10–95 % RH, non-condensing
Interfaces USB
Internal memory Over 2,000,000 measured values
PC requirement Windows 10 or higher for current MSR PC Software Pro
Relative humidity range 0–100 % RH
Humidity accuracy H3/FH3 ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C)
Humidity sensor temperature limits Internal: −20 to +65 °C
Humidity interval 1 second to 12 hours
Humidity sensor additional channel Integrated temperature
Humidity sensor temperature limits External: −40 to +125 °C; internal: −20 to +65 °C
Humidity interval 1 second to 12 hours
Humidity sensor additional channel Integrated temperature
Absolute air pressure range 10–2,000 mbar absolute
Air pressure accuracy ±2 mbar at 750–1,100 mbar absolute and +25 °C
Pressure sensor additional channel Integrated temperature
Air pressure interval 1 second to 12 hours
Acceleration 3 axes; ±15 g
Acceleration accuracy ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C
Acceleration recording interval 0.02 second to 12 hours

 

Included configuration

  • MSR145 data logger in the specified housing with rechargeable battery
  • Selected sensors and connections listed in this configuration
  • MSR PC software (download)
  • USB connection cable

Requirements and accessories

  • Windows 10 or higher with USB connection for current MSR PC Software Pro

Documents and resources