MSR145 IP67 Humidity, Air-Pressure and Acceleration Data Logger
Compact data logger with humidity, absolute air-pressure and three-axis acceleration sensors, plus temperature measurement integrated into the humidity and pressure sensors. Features an encapsulated housing, a 230 mAh rechargeable battery and USB readout.
The 145B16H3P5A records 0–100% relative humidity, absolute air pressure from 10 to 2,000 mbar and three-axis acceleration over ±15 g. Temperature measurement is integrated into the H3 and P5 sensors; the configuration has no separate T9 sensor. Internal sensors operate within −20 to +65 °C. Acceleration can be recorded up to 50 times per second, while humidity and pressure support one reading per second, with longer intervals selectable up to 12 hours.
The small B16 polycarbonate housing is encapsulated and rated IP67: dust-tight and protected against temporary immersion under specified test conditions. A 230 mAh battery is rechargeable via USB, and internal memory holds more than two million measured values. Use the included MSR PC Software Pro to configure the data logger and analyse the environmental and movement records.
Benefits
- Humidity, absolute air pressure and three-axis acceleration together
- Integrated temperature measurement without a separate temperature probe
- Acceleration recording up to 50 Hz
- Compact, encapsulated housing and 230 mAh rechargeable battery
- More than two million measured values and included PC software
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Product code | 145B16H3P5A |
| Housing | Polycarbonate, encapsulated |
| Protection rating | IP67 |
| Battery | 230 mAh rechargeable lithium-polymer |
| Charging | USB |
| Dimensions of data logger (W × H × L) | 27 × 16 × 53 mm |
| Approximate data logger housing weight | 27 g; connected sensor assemblies add weight |
| Operating temperature of data logger | −20 to +65 °C |
| Storage conditions | +5 to +45 °C; 10–95 % RH, non-condensing |
| Interfaces | USB |
| Internal memory | Over 2,000,000 measured values |
| PC requirement | Windows 10 or higher for current MSR PC Software Pro |
| Relative humidity range | 0–100 % RH |
| Humidity accuracy H3/FH3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Humidity sensor temperature limits | External: −40 to +125 °C; internal: −20 to +65 °C |
| Humidity interval | 1 second to 12 hours |
| Humidity sensor additional channel | Integrated temperature |
| Absolute air pressure range | 10–2,000 mbar absolute |
| Air pressure accuracy | ±2 mbar at 750–1,100 mbar absolute and +25 °C |
| Pressure sensor additional channel | Integrated temperature |
| Air pressure interval | 1 second to 12 hours |
| Acceleration | 3 axes; ±15 g |
| Acceleration accuracy | ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C |
| Acceleration recording interval | 0.02 second to 12 hours |
| Light range | 0–83,000 lx |
| Light sensitivity | Maximum at 550 nm |
| Light interval | 1 second to 12 hours |
Included configuration
- MSR145 data logger in the specified housing with rechargeable battery
- Selected sensors and connections listed in this configuration
- MSR PC software (download)
- USB connection cable
Requirements and accessories
- Windows 10 or higher with USB connection for current MSR PC Software Pro