MSR145 Strain-Gauge Data Logger with 20 cm Connection
Data logger with one 20 cm connection for a compatible full-bridge strain gauge, a 3 V bridge supply and a 1000 mAh rechargeable battery. Stores more than two million measured values; the strain gauge is not included.
This MSR145 configuration is equipped with one FD/020 connection for a full-bridge strain gauge on a 20 cm cable. The connection supplies a 3 V bridge voltage and records at intervals from one second to 12 hours. It provides the recording instrument and connection for a compatible strain gauge; the gauge itself is not part of this configuration.
The B7 housing contains a 1000 mAh rechargeable battery and memory for more than two million measured values. Its polycarbonate enclosure has an IP60 rating, meaning it is dust-tight but has no water-protection rating. Charge and read out the data logger through USB, and use the included MSR PC Software Pro for setup and measurement analysis. Compatibility of the intended bridge must be checked against the confirmed FD specification before use.
Benefits
- One dedicated connection for a full-bridge strain gauge
- 20 cm cable and 3 V bridge supply
- 1000 mAh rechargeable battery
- More than two million measured values in internal memory
- USB configuration and analysis with MSR PC Software Pro
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Product code | 145B7 & FD/020 |
| Housing | Polycarbonate, not encapsulated |
| Protection rating | IP60 |
| Battery | 1000 mAh rechargeable lithium-polymer |
| Charging | USB |
| Dimensions of data logger (W × H × L) | 39 × 23 × 72 mm |
| Approximate data logger housing weight | 56 g; connected sensor assemblies add weight |
| Operating temperature of data logger | −20 to +65 °C |
| Storage conditions | +5 to +45 °C; 10–95 % RH, non-condensing |
| Interfaces | USB |
| Internal memory | Over 2,000,000 measured values |
| PC requirement | Windows 10 or higher for current MSR PC Software Pro |
| Strain gauge connection | Full bridge; rated output 1–4 mV/V; bridge voltage 3 V |
| Strain gauge interval | 1 second to 12 hours |
| External component FD/020 | 1 × FD/020; cable 20 cm |
| Relative humidity range | 0–100 % RH |
| Humidity accuracy H3/FH3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Humidity sensor temperature limits | External: −40 to +125 °C; internal: −20 to +65 °C |
| Humidity interval | 1 second to 12 hours |
| Humidity sensor additional channel | Integrated temperature |
| Absolute air pressure range | 10–2,000 mbar absolute |
| Air pressure accuracy | ±2 mbar at 750–1,100 mbar absolute and +25 °C |
| Pressure sensor additional channel | Integrated temperature |
| Air pressure interval | 1 second to 12 hours |
| Acceleration | 3 axes; ±15 g |
| Acceleration accuracy | ±0.15 g (0–5 g), ±0.25 g (5–10 g), ±0.45 g (10–15 g), at +25 °C |
| Acceleration recording interval | 0.02 second to 12 hours |
Included configuration
- MSR145 data logger in the specified housing with rechargeable battery
- Selected sensors and connections listed in this configuration
- MSR PC software (download)
- USB connection cable
Requirements and accessories
- Windows 10 or higher with USB connection for current MSR PC Software Pro
- Compatible full-bridge strain gauge; the product code specifies the connection, not a strain gauge sensor