Compact four-sensor data logger for temperature, humidity, absolute air pressure and light. Records up to once per second, stores more than two million measured values and uses a USB-rechargeable 230 mAh battery.
The 145B15T9H3P5L3 records four environmental quantities together: temperature from −20 to +65 °C, relative humidity from 0–100%, absolute air pressure from 10–2,000 mbar and light from 0–83,000 lx. The light channel adds an illumination record alongside the temperature, humidity and pressure data. All four sensor types support recording intervals from one second to 12 hours, with space for more than two million measured values internally.
The B15 polycarbonate housing contains a 230 mAh rechargeable battery and has an IP60 rating: dust-tight, with no water-protection rating. USB is used for charging and reading out recordings. The included MSR PC Software Pro provides configuration and analysis, while the push-button and LEDs support operation and status checks at the device.
Benefits
- Light measurements alongside temperature, humidity and absolute air pressure
- Light range up to 83,000 lx
- Recording intervals from one second to 12 hours
- Compact 230 mAh rechargeable configuration
- More than two million measured values and USB analysis
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Product code | 145B15T9H3P5L3 |
| Housing | Polycarbonate, not encapsulated |
| Protection rating | IP60 |
| Battery | 230 mAh rechargeable lithium-polymer |
| Charging | USB |
| Dimensions of data logger (W × H × L) | 27 × 16 × 53 mm |
| Approximate data logger housing weight | 20 g; connected sensor assemblies add weight |
| Operating temperature of data logger | −20 to +65 °C |
| Storage conditions | +5 to +45 °C; 10–95 % RH, non-condensing |
| Interfaces | USB |
| Internal memory | Over 2,000,000 measured values |
| PC requirement | Windows 10 or higher for current MSR PC Software Pro |
| Internal temperature range | −20 to +65 °C |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Temperature interval | 1 second to 12 hours |
| Relative humidity range | 0–100 % RH |
| Humidity accuracy H3/FH3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Humidity sensor temperature limits | External: −40 to +125 °C; internal: −20 to +65 °C |
| Humidity interval | 1 second to 12 hours |
| Humidity sensor additional channel | Integrated temperature |
| Absolute air pressure range | 10–2,000 mbar absolute |
| Air pressure accuracy | ±2 mbar at 750–1,100 mbar absolute and +25 °C |
| Pressure sensor additional channel | Integrated temperature |
| Air pressure interval | 1 second to 12 hours |
| Light range | 0–83,000 lx |
| Light sensitivity | Maximum at 550 nm |
| Light interval | 1 second to 12 hours |