MSR165 IP67 Shock and Vibration Data Logger, ±200 g, with Temperature
Three-axis shock and vibration data logger for acceleration up to ±200 g, recording at up to 1,600 Hz. Includes temperature measurement, 32 pre-trigger values and a 1000 mAh USB-rechargeable battery.
The 165B8T9A3 uses the ±200 g acceleration sensor for measuring higher-amplitude shocks and vibrations in three axes. It records acceleration at up to 1,600 readings per second and retains 32 measured values before a shock trigger. The internal temperature sensor adds a −20 to +65 °C record at intervals from one second to 12 hours. More than two million measured values can be stored internally.
The encapsulated B8 housing is rated IP67: dust-tight and protected against temporary immersion under specified test conditions. A 1000 mAh rechargeable battery is charged through USB. MSR quotes up to six months of shock monitoring with this battery type, subject to the recording setup and conditions. Included MSR PC software supports configuration and readout; ShockViewer provides graphical evaluation and reports for shock-mode data. This is the ±200 g sensor configuration, not a device with two simultaneous acceleration ranges.
Benefits
- ±200 g sensor for higher-amplitude shocks and vibrations
- Three-axis acceleration recording up to 1,600 Hz
- 32 pre-trigger values retain the start of a shock
- Temperature recording and more than two million values of memory
- Encapsulated housing and USB-rechargeable 1000 mAh battery
Applications
- Transport monitoring
- Machine fault diagnosis
- Load and vibration investigations
CONFIGURE YOUR OWN DEVICE >>
Technical specifications
| Manufacturer | MSR Electronics GmbH |
|---|---|
| Model family | MSR165 |
| Product code | 165B8T9A3 |
| Memory | More than 2,000,000 measured values internally |
| Acceleration range | ±200 g, three axes |
| Acceleration resolution | 13 bit |
| Acceleration measurement/storage rate | Up to 1,600/s (±15%) to every 12 h |
| Acceleration accuracy at +25 °C | ±2 g (0–15 g); ±5 g (15–100 g); ±10 g (100–200 g) |
| Pre-trigger recording | 32 values before the shock event |
| Temperature range | −20 to +65 °C |
| Environmental sensor recording interval | 1 second to 12 hours |
| Operating temperature | −20 to +65 °C |
| Interface | USB |
| Dimensions (W × H × L) | 39 × 23 × 72 mm |
| Approximate weight | 69 g |
| Battery | 1,000 mAh rechargeable LiPo |
| Housing/protection | Anodised aluminium/PC; IP67 |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Housing/protection | Anodised aluminium/PC; IP67 |
| Temperature accuracy T9 | ±0.1 °C (−25 to +55 °C); ±0.3 °C (−40 to +125 °C); data logger operating limits apply |
| Humidity accuracy H3 | ±2 % RH (10–80 % RH, +25 °C); ±3 % RH (80–100 % RH, +25 °C) |
| Air pressure accuracy P5 | ±2 mbar (750–1,100 mbar absolute, +25 °C) |
| Static acceleration accuracy at +25 °C | ±0.15 g (0–5 g); ±0.25 g (5–10 g); ±0.45 g (10–15 g) |
Included configuration
- 1 × MSR165 data logger configured as 165B8T9A3
- Specified battery supply
- MSR PC software available for download
- USB cable
- Screw set
- Transport case
- Quick start guide
Requirements and accessories
- Windows PC with USB port for configuration and data evaluation; verify current supported OS release